ME15P

Multi-Channel
Electrocardiograph

The new 15-channel ECG aids in detection of ECG changes of ischemia which are difficult to be detected with standard 12 channel ECG. It can deliver high-quality clinical performance no matter when and where you need it, which can help you to simplify cardiac patient care. It is the pertect ECG to have for emergency room departaments and critical care units.

ME15P (1)

Main Features:

» Compact and elegant notebook design.
» 12.1-inch high resolution TFT LCD with touch screen, easy to view.
» Full alphanumeric keyboard with shortcut keys, efficient in operation.
» Broad frequency response 0.05-250Hz for weaker signal recognition and capture, more suitable for pediatrics.
» 15-lead ECG for adults and pediatrics, Vector cardiograph, 12-lead ECG, all-in-one.

» VCG and vector loop for more advantages in diagnosis of
the right atrium & ventricular hypertrophy, conduction block,
myocardial infarction and so on.
» New generation acquisition module, more quickly, stable
and accurate in ECG signal process.
» New filtering technology effectively guarantees waveforms
against AC interference, wandering and overlapping.
» Massive local storage for up to 1500 files.
» Apply the latest Minnesota code.
»7 working modes catering for clinical demands.
» 18 report formats on printing.
» 3 ways of file storage: local memory, SD card, USB flash disk.

Technical Specifications
ECG interpretation
ME15P Digital Electrocardiograph ECG analysis program for adults and pediatrics
Acquisition mode
Simultaneous standard 12-lead in pre-acquisition or post-acquisition
A/D conversion
24 bit
Sampling rate
8,000 samples/s
Frequency response
0.01 Hz~300 Hz
Common mode rejection ratio
>105dB
Polarization voltage
± 550 mV
Input circuit
Floating circuit input
Input impedance
≥50 MΩ
Input CIR current
≤0.1 μA
Patient leakage current
<10 μA
Time constant
≥3.2 s
Noise level
≤15 μVp-p
Sensitivity threshold
≤20 μV
Calibration voltage
1 mV±5 %
Filter setting
EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
AC filter
50Hz, 60Hz
Heart rate range
30~300 bpm
Acquisition time
10~24 seconds
ECG interpretation
ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics
Acquisition mode
Simultaneous standard 12-lead in pre-acquisition or post-acquisition
A/D conversion
24 bit
Sampling rate
8,000 samples/s
Frequency response
0.05 Hz~250 Hz
Common mode rejection ratio
>105dB
Polarization voltage
± 550 mV
Input circuit
Floating circuit input
Input impedance
≥50 MΩ
Input CIR current
≤0.1 μA
Patient leakage current
<10 μA
Time constant
≥3.2 s
Noise level
≤15 μVp-p
Sensitivity threshold
≤20 μV
Calibration voltage
1 mV±5 %
Filter setting
EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
AC filter
50Hz, 60Hz
Heart rate range
30~300 bpm
Acquisition time
10~24 seconds
Display type
8.9 inch TFT LCD with touch screen
Display resolution
1280×768
AC power supply
AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA
Battery power supply
Rechargeable lithium battery, 14.8V, 4400mAh
Recorder resolution
8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s)
Recorder speed
(5, 6.25, 10, 12.5, 25, 50) mm/s±5 %
Recording paper
Z- fold paper: 210mm×150mm×140p
Measurement values
HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage
DEMO mode
Normal ECG, Arrhythmia ECG
QTC formula
Bazett, Fridercia, Framingham, Hodges
Data format
ECG, DICOM, XML, JPEG, PDF
External peripheral use
Patient cable socket
SD card port
Two USB port
LAN port
VGA port
Dimensions and weight
Size
345mm x 260mm x 128.5 mm
Weight
About 3.4 kg
Pacemaker Detection
Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
Preview Function
Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
R-R Analysis
*30-300 seconds for R-R analysis, better in arrhythmia diagnosis
*Up to 200 kinds of arrhythmia analysis
Waveform Freezing
*300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print.
*lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on.