ME12P
Multi-Channel
Electrocardiograph
Is a new type of 12-channel ECG which has made a lot of improvement in the key ECG technologies of quickness, accuracy and stability as well as the streamlined workflow. It applies a new platform for ECG signal acquisition, which can perform well in interface reduction, fast waveform display and right level of filtering.

Features
» 12-channels ECG
» 8.9 inch TFT LCD touch screen
» 60 degree viewing angle adjustable
» Full alphanumeric waterproof silicone keyboard
» Abundant Peripheral interfaces: VGA, LAN, USB, SD CARD
» ECG data management software
» High resolution Printer A4 paper size
» Storage: 1500 ECG Files
» Rechargeable Li-ion battery, 14.8V-4400mAh
» ECG data management software
» High resolution Printer A4 paper size
» Storage: 1500 ECG Files
» Rechargeable Li-ion battery, 14.8V-4400mAh
Technical Specifications
Technical Specifications
Display specifications
Power supply
Recorder specifications
Standard software specifications
Dimensions and weight
ECG interpretation | ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.05 Hz~250 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |
Technical Specifications
ECG interpretation | ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.05 Hz~250 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display specifications
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
Power supply
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder specifications
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Standard software specifications
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |