Blu12+
Multi-Parameter
Patient Monitor
Easy to use Multi-Parameter Patient Monitor, dedicated to In-hospital applications including emergency room pre and post-operative care, ICU, Operating room/theatre, ambulatory surgery, intermediate care/step down units, labour & delivery, and hospital based special procedure areas.
Features
» Multi-channel waveform display.
» Portable operation, multi-pronged.
» Full-screen touch, fingertip operation.
» Fast button backlit design for easy night operation.
» Ergonomic knob operation, classic and flexible.
» Plugin & use, powerful 2 module slots, easy to upgrade.
» Flexible combination, resource sharing.
» Global gold standard Masimo SpO2, ensures low perfusion measurement.
» Sun tech NIBP blood pressure, accurate blood pressure measurement.
Anesthesia Monitoring
The latest respiratory gas and brain activity monitoring technology for the most reliable performance during surgeries.
Respiratory Monitoring
Industry-leading CO2 & RM monitoring technology provides the most flexible and accurate solutions for both the intubated and non-intubated patients.
Cardiac Monitoring
Mediblu’s ECG algorithm, together with ICG technology allows for flexible and reliable measurements on even the extreme cardiac cases.
Emergency Cases
The modular design and the expanded parameter configurations extend possibilities in ICU/ER monitoring on a case-to-case basis.
Performance and Technical Specifications
General |
---|
*Size: 318x264x152mm *Weight ≤ 4.5kg *Display 12.1” Color TFT – Resolution 600 pixels *Intelligent audio, three level, and Visual, Red Led, comprehensive alarm |
Environment |
---|
*Working temperature: 0-+40°C Storage temperature: -20-+50 °C *Safety IEC60601 Approved |
Power Requirement |
---|
*Power Voltage AC 100-240V 50/60Hz; DC 12V (Optional) *Power Rate 80VA *Operating time under normal use ≥ 3 Hours Charge time 6 Hours |
Thermal Printer (Option) |
---|
*Method: Thermal dot array with 3 tracks *Paper width: 50 mm with Paper Speed of 12.5/25/50 (mm/sec) |
System output |
---|
*Ethernet Network standard RJ45 socket; Defibrillation Out. BNC connector *USB 2 sockets; Video Output 1VGA (Option); Nurse call 1 Rj11 connector |
Data Storage & Reviewing |
---|
*Trend: Land trend: 168h,min.resolution is 1min (store when power goes off) *NIBP measurement reviewing: 1000 groups *ARR event: 128 groups of ARR event and the associated waveform. *Alarm events:128 groups of parameter alarm events and associated parameter waveform at the alarm moment *Full Disclosure waveform: 96 hours for 3 waveforms{with 4G SD card) |
ECG |
---|
*Mode: 3/5/12-leads *Lead selection: I, II, III, aVR, aVL, aVF, V1-V6 (option) *Gain selection: AUTO, 0.25x, 0.50x, 1.0x, 2.0x, 4.0x *Sweep speed: 6,25mm/s,12,5mm/s,25mm/s,50mm/s *Heart Rate:15-300 bpm –HR accuracy: ± 1 % *ST segment deviation analysis: -0.8-+0.8mV *ST accuracy: ±0.02mv |
General |
---|
*Size: 318x264x152mm *Weight ≤ 4.5kg *Display 12.1” Color TFT – Resolution 600 pixels *Intelligent audio, three level, and Visual, Red Led, comprehensive alarm |
Environment |
---|
*Working temperature: 0-+40°C Storage temperature: -20-+50 °C *Safety IEC60601 Approved |
Power Requirement |
---|
*Power Voltage AC 100-240V 50/60Hz; DC 12V (Optional) *Power Rate 80VA *Operating time under normal use ≥ 3 Hours Charge time 6 Hours |
Thermal Printer (Option) |
---|
*Method: Thermal dot array with 3 tracks *Paper width: 50 mm with Paper Speed of 12.5/25/50 (mm/sec) |
System output |
---|
*Ethernet Network standard RJ45 socket; Defibrillation Out. BNC connector *USB 2 sockets; Video Output 1VGA (Option); Nurse call 1 Rj11 connector |
Data Storage & Reviewing |
---|
*Trend: Land trend: 168h,min.resolution is 1min (store when power goes off) *NIBP measurement reviewing: 1000 groups *ARR event: 128 groups of ARR event and the associated waveform. *Alarm events:128 groups of parameter alarm events and associated parameter waveform at the alarm moment *Full Disclosure waveform: 96 hours for 3 waveforms{with 4G SD card) |
ECG |
---|
*Mode: 3/5/12-leads *Lead selection: I, II, III, aVR, aVL, aVF, V1-V6 (option) *Gain selection: AUTO, 0.25x, 0.50x, 1.0x, 2.0x, 4.0x *Sweep speed: 6,25mm/s,12,5mm/s,25mm/s,50mm/s *Heart Rate:15-300 bpm –HR accuracy: ± 1 % *ST segment deviation analysis: -0.8-+0.8mV *ST accuracy: ±0.02mv |