HA12P
ECG Holter System
Function
» The recorder can real-time store ECG data for 24-hour.
» Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
» Sync analysis for 12-lead, which ensures that QRS waveform can be found accurately, and no distortion.
» With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
» Flexible analysis channel selection function, which
ensures that any channels can be selected as the main
he analysis channel.
» Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/ manual analysis, more accurate in atrial fibrillation analysis.
» All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
» With many pacing analysis templates, such as «Dual chamber pacing» «Atrial pacing», Ventricular pacing», «Ventricular Pseudofusion» and «Ventricular asynchronous pacing», etc.
» Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
» With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
» One-key print, convenient and fast to print the reports.
» Perfect case management function.
Technical Specifications
ECG interpretation | ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.05 Hz~250 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |
ECG interpretation | ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.05 Hz~250 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |