HA50P

HA50P Blood Pressure Holter System

Mediblu blood pressure holter system is a
portable MAPA monitor, which is designed
according to oscillography theory. The
device could monitor human body blood
pressure up to 24 hours continuously and
dynamically, providing accurate basis for the
diagnosis. It is light and applicable for use
anywhere from cardiac hospitals to General
Practioners clinics.

Features

» Compact and portable, user-friend interface, easy to use
» Patient range: adult, pediatric, neonate
» 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be recorded for once.
» Perfect combination of automatic and manual measurement method, up to 300 groups of data can be recorded for once by manual measure.
» High-definition color TFT display, strong visibility
» By data review interface such as «data list»,»trend graph»,»big font», NIBP data is clear at a glance
» Display of low power prompt, alarm, error message and time
» Supply two kinds of unit: mmHg / kPa
» Display interface can be switched between Chinese and English
» Parameter alarm dispose function is optional
» Communicate with PC, PC software can achieve data review, measured results analysis, view of trend graph, reports printing and other functions

Technical Specifications
ECG interpretation
ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics
Acquisition mode
Simultaneous standard 12-lead in pre-acquisition or post-acquisition
A/D conversion
24 bit
Sampling rate
8,000 samples/s
Frequency response
0.05 Hz~250 Hz
Common mode rejection ratio
>105dB
Polarization voltage
± 550 mV
Input circuit
Floating circuit input
Input impedance
≥50 MΩ
Input CIR current
≤0.1 μA
Patient leakage current
<10 μA
Time constant
≥3.2 s
Noise level
≤15 μVp-p
Sensitivity threshold
≤20 μV
Calibration voltage
1 mV±5 %
Filter setting
EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
AC filter
50Hz, 60Hz
Heart rate range
30~300 bpm
Acquisition time
10~24 seconds
ECG interpretation
ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics
Acquisition mode
Simultaneous standard 12-lead in pre-acquisition or post-acquisition
A/D conversion
24 bit
Sampling rate
8,000 samples/s
Frequency response
0.05 Hz~250 Hz
Common mode rejection ratio
>105dB
Polarization voltage
± 550 mV
Input circuit
Floating circuit input
Input impedance
≥50 MΩ
Input CIR current
≤0.1 μA
Patient leakage current
<10 μA
Time constant
≥3.2 s
Noise level
≤15 μVp-p
Sensitivity threshold
≤20 μV
Calibration voltage
1 mV±5 %
Filter setting
EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
AC filter
50Hz, 60Hz
Heart rate range
30~300 bpm
Acquisition time
10~24 seconds
Display type
8.9 inch TFT LCD with touch screen
Display resolution
1280×768
AC power supply
AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA
Battery power supply
Rechargeable lithium battery, 14.8V, 4400mAh
Recorder resolution
8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s)
Recorder speed
(5, 6.25, 10, 12.5, 25, 50) mm/s±5 %
Recording paper
Z- fold paper: 210mm×150mm×140p
Measurement values
HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage
DEMO mode
Normal ECG, Arrhythmia ECG
QTC formula
Bazett, Fridercia, Framingham, Hodges
Data format
ECG, DICOM, XML, JPEG, PDF
External peripheral use
Patient cable socket
SD card port
Two USB port
LAN port
VGA port
Dimensions and weight
Size
345mm x 260mm x 128.5 mm
Weight
About 3.4 kg
Pacemaker Detection
Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
Preview Function
Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
R-R Analysis
*30-300 seconds for R-R analysis, better in arrhythmia diagnosis
*Up to 200 kinds of arrhythmia analysis
Waveform Freezing
*300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print.
*lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on.