ME15P
Multi-Channel
Electrocardiograph
The new 15-channel ECG aids in detection of ECG changes of ischemia which are difficult to be detected with standard 12 channel ECG. It can deliver high-quality clinical performance no matter when and where you need it, which can help you to simplify cardiac patient care. It is the pertect ECG to have for emergency room departaments and critical care units.
Main Features:
» Compact and elegant notebook design.
» 12.1-inch high resolution TFT LCD with touch screen, easy to view.
» Full alphanumeric keyboard with shortcut keys, efficient in operation.
» Broad frequency response 0.05-250Hz for weaker signal recognition and capture, more suitable for pediatrics.
» 15-lead ECG for adults and pediatrics, Vector cardiograph, 12-lead ECG, all-in-one.
» VCG and vector loop for more advantages in diagnosis of
the right atrium & ventricular hypertrophy, conduction block,
myocardial infarction and so on.
» New generation acquisition module, more quickly, stable
and accurate in ECG signal process.
» New filtering technology effectively guarantees waveforms
against AC interference, wandering and overlapping.
» Massive local storage for up to 1500 files.
» Apply the latest Minnesota code.
»7 working modes catering for clinical demands.
» 18 report formats on printing.
» 3 ways of file storage: local memory, SD card, USB flash disk.
Technical Specifications
ECG interpretation | ME15P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.01 Hz~300 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |
ECG interpretation | ME12P Digital Electrocardiograph ECG analysis program for adults and pediatrics |
---|---|
Acquisition mode | Simultaneous standard
12-lead in pre-acquisition or post-acquisition
|
A/D conversion | 24 bit |
Sampling rate | 8,000 samples/s |
Frequency response | 0.05 Hz~250 Hz |
Common mode rejection ratio | >105dB |
Polarization voltage | ± 550 mV |
Input circuit | Floating circuit input |
Input impedance | ≥50 MΩ |
Input CIR current | ≤0.1 μA |
Patient leakage current | <10 μA |
Time constant
| ≥3.2 s |
Noise level | ≤15 μVp-p |
Sensitivity threshold | ≤20 μV |
Calibration voltage | 1 mV±5 % |
Filter setting | EMG filter: 25 / 35 / 75 / 100 / 150 / 250Hz
Baseline wander filter: 0.01 / 0.02 / 0.05 / 0.35 / 0.5 / 0.8Hz
|
AC filter | 50Hz, 60Hz
|
Heart rate range | 30~300 bpm |
Acquisition time | 10~24 seconds |
Display type | 8.9 inch TFT LCD with touch screen |
---|---|
Display resolution | 1280×768
|
AC power supply | AC / DC 100 V~240 V, 50 Hz /60 Hz, 110 VA |
---|---|
Battery power supply
| Rechargeable lithium battery, 14.8V, 4400mAh |
Recorder resolution | 8 points/mm (perpendicular), 40 points/mm (horizontal, 25 mm/s) |
---|---|
Recorder speed | (5, 6.25, 10, 12.5, 25, 50) mm/s±5 % |
Recording paper | Z- fold paper: 210mm×150mm×140p
|
Measurement values | HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage |
---|---|
DEMO mode | Normal ECG, Arrhythmia ECG
|
QTC formula | Bazett, Fridercia, Framingham, Hodges |
Data format | ECG, DICOM, XML, JPEG, PDF
|
External peripheral use | Patient cable socket SD card port Two USB port LAN port VGA port |
Dimensions and weight | |
---|---|
Size | 345mm x 260mm x 128.5 mm
|
Weight | About 3.4 kg |
Pacemaker Detection | Through ECG waveforms display and analysis, doctors can determine the pacemaker type and work status through the ECG analysis.
|
Preview Function | Doctors can preview the waveforms and analysis results directly on the screen then decide whether to print or not, good for faster treatment and cost-saving.
|
R-R Analysis | *30-300 seconds for R-R analysis, better in arrhythmia diagnosis *Up to 200 kinds of arrhythmia analysis |
Waveform Freezing | *300 seconds for waveform freezing and cine-loop, any 10 seconds selectable for analysis and print. *lt is significant when testing Children, fracture patients, aged people whose skin is too dry to connect the electrodes and so on. |