MO1
Pulse Oximeter
Lightweight & Easy to Use,1.8” high definition LCD color screen, spot-check and continuous monitoring of SpO2 and pulse rate.
Features
» Real-time SpO2 waveform.
» SpO2 & PR value and intensity.
» Fast, accurate, stable & strong anti-interference performance.
» At least 48 hours parameter & trend data storage, up to 999 measuring objects.
» PC connection to download & analyze/print data.
» Suitable for adult, pediatric & neonatal use.
» Real time clock.
» Automatically recharges battery upon circuit connection.
» 10-12 hours battery back-up, Real capacity indication.
» Visual and acoustic Abnormal Parameter Alarm.
Technical Specifications
Technical Specifications
Performance Index SpO2% | * Measurement Range: 0 ~ 100% * Measurement Accuracy: ±2 % at 70% ~ 100% * No indication at 0% ~ 69% |
---|---|
Pulse rate | * Measurement Range: 30 bpm ~ 250 bpm * Measurement Accuracy: ±1 bpm or ±2%; whichever is greater |
Probe type: | * LED red wavelength: 660nm * LED infrared wavelength: 880~940nm |
Environmental Requirements | * Temperature Range: * Operating: (-10 ~ + 40) ℃ * Transport/Storage: (- 40 ~ + 55) ℃ |
Relative Humidity (non-condensing) | * Operating: 0 ~ 93 % * Transport/Storage: 0 ~ 95 % |
Protection Model / Equipment classification | CLASS II EQUIPMENT |
INTERNALLY POWERED EQUIPMENT | Protection degree: BF type * Outside surface protection degree: IPX0 * Operating model: continuous |
Power Requirements | * Battery: Four standard “ AA” size rechargeable NiMH batteries are applied on MO1, (Such as GPI INTERNATIONAL LIMITED GP200AAH) * Input voltage: 100~240V AC 50/60Hz * Input power: 14VA |
Continuous operating time | Internal power operating time: ≥ 10h |
Size and Weight | * Size: 135mm(L) Å~ 67mm(W) Å~ 31mm(H) * Weight (with batteries installed): 430g * (Without batteries): 314g |
Technical Specifications
Performance Index SpO2% | * Measurement Range: 0 ~ 100% * Measurement Accuracy: ±2 % at 70% ~ 100% * No indication at 0% ~ 69% |
---|---|
Pulse rate | * Measurement Range: 30 bpm ~ 250 bpm * Measurement Accuracy: ±1 bpm or ±2%; whichever is greater |
Probe type: | * LED red wavelength: 660nm * LED infrared wavelength: 880~940nm |
Environmental Requirements | * Temperature Range: * Operating: (-10 ~ + 40) ℃ * Transport/Storage: (- 40 ~ + 55) ℃ |
Relative Humidity (non-condensing) | * Operating: 0 ~ 93 % * Transport/Storage: 0 ~ 95 % |
Protection Model / Equipment classification | CLASS II EQUIPMENT |
INTERNALLY POWERED EQUIPMENT | Protection degree: BF type * Outside surface protection degree: IPX0 * Operating model: continuous |
Power Requirements | * Battery: Four standard “ AA” size rechargeable NiMH batteries are applied on MO1, (Such as GPI INTERNATIONAL LIMITED GP200AAH) * Input voltage: 100~240V AC 50/60Hz * Input power: 14VA |
Continuous operating time | Internal power operating time: ≥ 10h |
Size and Weight | * Size: 135mm(L) Å~ 67mm(W) Å~ 31mm(H) * Weight (with batteries installed): 430g * (Without batteries): 314g |